Hydrostatic Level Probe FRIPRO P135
Technical Description
Hydrostatic level sensor with front flush ceramic diaphragm, 22mm housing diameter.
Cable according to Bg VV-1.12.96-recommendation food and drinking water suitable
optional integrated Pt 100 / Pt 1000 sensor for measuring temperature.
For more options, ATEX authorization and integrated lightning protection
22 mm ideal for 1“ pipes
Typical application areas tested
● Continuous level measurement in open save containers in water supply and
wastewater disposal, has dams, weir systems, wells e.c.
Standard measuring ranges Table 1
Technical data
FRIPRO P 135
|
|
|
Ranges
|
|
0...100 mbar to 0...20 bar |
Output signal
|
|
4...20 mA, 2-wire |
Accuracy |
|
≤ ± 0,2% FS @ 25°C
|
Response time |
|
200 ms (other available on request) |
Supply voltage
|
|
12...30V DC |
Ambient temperature
|
|
-25...80 °C (-20...70 °C at EEx ia IIC T4) |
Temperature coef. |
|
≤ ± 0,02% FS/K |
Long term stability |
|
≤ ± 0.2% FS p. a. |
Housing |
|
stainless steel, 1.4404, IP 68 |
Weight of probe
|
|
ca. 0,3 kg |
Weight of cable |
|
0,5 kg / 10 m |
Electrical connection
|
|
PE cable with pressure compensation capillary and filter |
Dimensions
Typ A
Typ B
Electrical connections
|
Figure Hydrostatic level probe dia 22 mm
Figure Pressure diaphragm
dia 22 mm
upward |